Our website uses cookies to enhance your browsing experience.
Accept
to the top
>
>
>
V537. Potential incorrect use of item '…
menu mobile close menu
Analyzer diagnostics
General Analysis (C++)
General Analysis (C#)
General Analysis (Java)
Micro-Optimizations (C++)
Diagnosis of 64-bit errors (Viva64, C++)
Customer specific requests (C++)
MISRA errors
AUTOSAR errors
OWASP errors (C++)
OWASP errors (C#)
Problems related to code analyzer
Additional information
toggle menu Contents

V537. Potential incorrect use of item 'X'. Consider inspecting the expression.

Jun 14 2012

The analyzer has detected a potential misprint in code related to incorrect use of similar names.

This rule tries to diagnose an error of the following type using the heuristic method:

int x = static_cast<int>(GetX()) * n;
int y = static_cast<int>(GetX()) * n;

In the second line, the 'GetX' function is used instead of 'GetY'. This is the correct code:

int x = static_cast<int>(GetX()) * n;
int y = static_cast<int>(GetY()) * n;

To detect this suspicious fragment, the analyzer followed this logic: we have a line containing a name that includes the 'x' fragment. Beside it, there is a line that has a similar name with 'y'. But this second line has 'X' as well. Since this condition and some other conditions hold, the construct must be reviewed by the programmer. This code would not be considered dangerous if, for instance, there were no variables 'x' and 'y' to the left. This is a code sample the analyzer ignores:

array[0] = GetX() / 2;
array[1] = GetX() / 2;

Unfortunately, this rule often produces false alarms since the analyzer does not know how the program is organized and what the code's purpose is. This is a sample of a false alarm:

halfWidth -= borderWidth + 2;
halfHeight -= borderWidth + 2;

The analyzer supposed that the second line must be presented by a different expression, for instance, 'halfHeight -= borderHeight + 2'. But actually there is no error here. The border's size is equal in both vertical and horizontal positions. There is just no 'borderHeight' constant. However, such high-level abstractions are not clear to the analyzer. To suppress this warning, you may type the '//-V537' comment into the code.

You can use another technique to prevent false positives. Below is the code fragment:

bsdf->alpha_x = closure->alpha_x;
bsdf->alpha_y = bsdf->alpha_x;

The code is correct. However, it looks suspicious, and not only from the analyzer's viewpoint. The developer who maintains the code will have a hard time understanding it. If you want to assign the same value to 'alpha_x' and 'alpha_y', you can write the following:

bsdf->alpha_y = bsdf->alpha_x = closure->alpha_x;

This fragment won't confuse the developer and the analyzer won't issue a warning.

This diagnostic is classified as:

You can look at examples of errors detected by the V537 diagnostic.

close form

Fill out the form in 2 simple steps below:

Your contact information:

Step 1
Congratulations! This is your promo code!

Desired license type:

Step 2
Team license
Enterprise license
** By clicking this button you agree to our Privacy Policy statement
close form
Request our prices
New License
License Renewal
--Select currency--
USD
EUR
* By clicking this button you agree to our Privacy Policy statement

close form
Free PVS‑Studio license for Microsoft MVP specialists
* By clicking this button you agree to our Privacy Policy statement

close form
To get the licence for your open-source project, please fill out this form
* By clicking this button you agree to our Privacy Policy statement

close form
I am interested to try it on the platforms:
* By clicking this button you agree to our Privacy Policy statement

close form
check circle
Message submitted.

Your message has been sent. We will email you at


If you do not see the email in your inbox, please check if it is filtered to one of the following folders:

  • Promotion
  • Updates
  • Spam